Frag' FlorenceEvidenz. Klar. Anwendbar.
Uhr 7/8Sources Journal Tree
Easy Demo

Lokaler Crossref-Datenbestand · journal-article

Erratum: “Image guidance for FLASH Radiotherapy” https://doi.org/10.1002/mp.15662

Medical Physics · 2023

Aktualisierungshinweis vorhandenCrossref verzeichnet eine Korrektur, Aktualisierung oder Beziehung zu einer weiteren Version. Prüfen Sie den Status auf der Originalseite.

Vollständiger Abstract

Worum geht es in dieser Arbeit?

<h4>Background</h4>Boron Neutron Capture Therapy (BNCT) utilizes high linear energy transfer (LET) charged particles from the 10 B(n,α) 7 Li reaction to selectively destroy tumor cells. Unlike conventional radiation therapy, BNCT facilities rely on fixed beam ports, making patient positioning critical in treatment planning. Current treatment planning, however, depends on manual forward planning using computationally intensive Monte Carlo (MC) simulations.<h4>Purpose</h4>We propose an automated patient position optimization framework for BNCT to address these limitations. This method overcomes the computational bottleneck of MC simulations by integrating a rapid deep learning (DL) dose prediction model with a high-fidelity GPU-accelerated MC engine, enabling efficient inverse planning.<h4>Methods</h4>We developed a hybrid coarse-to-fine optimization workflow driven by the Trust Region Bayesian Optimization (TuRBO) algorithm. In the coarse stage, a 3D U-Net architecture rapidly identifies promising patient positions. In the fine stage, the solution is refined within a restricted parameter bound using the GPU-accelerated MC engine. We evaluated the framework on the GLIS-RT open dataset (229 glioblastoma patients, split into train, validation, and test sets at a 70:20:10 ratio).<h4>Results</h4>Optimizing the patient position with TuRBO improved target dose and homogeneity over a non-optimized baseline, reaching equivalent plan quality about 5.65× faster than an exhaustive grid search. In the coarse stage, the DL dose predictor ran about 37× faster than the high-fidelity MC. The coarse-to-fine workflow then matched high-fidelity MC plan quality while cutting optimization time by a factor of 2.7, outperforming optimization driven by the DL predictor alone. Two-port plans required no change to the method, where the added geometric freedom raised the mean target dose from 59.96% to 74.91% and lowered the homogeneity index (HI) from 1.226 to 0.647.<h4>Conclusions</h4>We successfully developed a Bayesian optimization (BO) framework for BNCT patient positioning. The proposed coarse-to-fine approach effectively balances computational speed with accuracy, offering a practical way toward automated inverse planning in BNCT.

Abstract: PubMed · Datensatz

Bibliografischer Nachweis

Publikationsdaten

Autor:innen
Nicht angegeben
Quelle
Medical Physics
Publikation
2023-01-01
Band / Ausgabe
Nicht angegeben
Seiten
Nicht angegeben
ISSN / ISBN
0094-2405, 2473-4209
Zitationen
2 laut Crossref
Referenzen
0 hinterlegt

Zitieren

Zitierfähiger Nachweis

(2023). Erratum: “Image guidance for FLASH Radiotherapy” https://doi.org/10.1002/mp.15662. Medical Physics. https://doi.org/10.1002/mp.70642
RIS BibTeX CSL-JSON

Kontext

Themen, Förderung und Nutzung

Lizenzhinweise: Lizenz 1