Frag' FlorenceEvidenz. Klar. Anwendbar.
Uhr 7/8Sources Journal Tree
Easy Demo

Lokaler Crossref-Datenbestand · journal-article

Improved Accuracy of Multidimensional Spatially‐Selective Saturation RF Pulses for Short‐Repetition‐Time Steady‐State Imaging

Yongli He, Douglas C. Noll, Jon‐Fredrik Nielsen

Magnetic Resonance in Medicine · 2026

Vollständiger Abstract

Worum geht es in dieser Arbeit?

ABSTRACT Purpose To introduce and evaluate a novel RF pulse design algorithm for multi‐dimensional spatially tailored excitation that is optimized for spoiled steady‐state gradient echo MRI sequences. Methods Existing multi‐dimensional RF pulse design algorithms optimize RF and gradient waveforms using a loss function based on a single RF pulse application. These designs are poorly suited for steady‐state MRI sequences where RF pulses are spaced only tens of milliseconds apart, causing potentially large differences between the steady‐state magnetization and the target pattern. We propose a multidimensional RF pulse design algorithm with a loss function based on the steady‐state magnetization of a spoiled gradient‐echo sequence. Our algorithm, steady‐state AutoDiffPulses (SS‐ADP), extends the previously introduced ADP framework for joint RF and gradient pulse design. We evaluated design accuracy and RF energy in phantom and in vivo brain imaging in inner‐volume (IV) and outer‐volume (OV) saturation experiments. We further evaluated the potential of SS‐ADP to improve reduced FOV (rFOV) imaging. Results SS‐ADP produced significantly more accurate steady‐state magnetization patterns compared to a conventional single‐excitation design (ADP), with significantly reduced RF energy, for . Furthermore, utilizing SS‐ADP for outer‐volume suppression (OVS) substantially reduced reconstruction error in accelerated rFOV imaging compared to conventional ADP‐OVS. Conclusion A joint RF and gradient pulse design algorithm accounting for steady‐state magnetization evolution significantly improves excitation accuracy and reduces SAR in short‐TR spoiled imaging with .

Bibliografischer Nachweis

Publikationsdaten

Autor:innen
Yongli He, Douglas C. Noll, Jon‐Fredrik Nielsen
Quelle
Magnetic Resonance in Medicine
Publikation
2026-01-01
Band / Ausgabe
Nicht angegeben
Seiten
Nicht angegeben
ISSN / ISBN
0740-3194, 1522-2594
Zitationen
0 laut Crossref
Referenzen
0 hinterlegt

Zitieren

Zitierfähiger Nachweis

Yongli He, Douglas C. Noll, Jon‐Fredrik Nielsen (2026). Improved Accuracy of Multidimensional Spatially‐Selective Saturation RF Pulses for Short‐Repetition‐Time Steady‐State Imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70573
RIS BibTeX CSL-JSON

Kontext

Themen, Förderung und Nutzung

Lizenzhinweise: Lizenz 1 · Lizenz 2