Frag' FlorenceEvidenz. Klar. Anwendbar.
Uhr 7/8Sources Journal Tree
Easy Demo

Lokaler Crossref-Datenbestand · journal-article

A comparison between two indices derived from automated pupillometry devices

Carlotta Bandoni, Khalil Mounir, Francesca Iannuzzi, Andrea Berardino, Fabio Tarantino, Mohammed Rabi Andaloussi, Fabio Silvio Taccone, Denise Battaglini, Nicolo ’ Antonino Patroniti, Chiara Robba

Journal of Clinical Monitoring and Computing · 2026

Vollständiger Abstract

Worum geht es in dieser Arbeit?

Abstract Automated pupillometry provides a standardised, quantitative, highly reproducible measurement of the pupillary light reactivity and other pupillary variables. The Neurologic pupillary index (NPi) has shown good prognostic value in patients with acute brain injury and cardiac arrest. However, few data on the comparison of NPi with a recently introduced index (quantitative pupillary index, QPI) are available. To compare the performance of two commercially available automated pupillometry devices, and in particular QPI and NPi, in a cohort of neuro-critically ill patients. Single-center observational study, including adult (> 18 years) patients admitted to a neuro-intensive care unit over a 6-month period. Pupillary reactivity was assessed in both eyes of each patient using the two pupillometers currently available, the Neuroptics NPi-300 (Neuroptics, Irvine, CA, USA) and the NeuroLight (ID-Med, Marseilles, France). A total of 73 patients were included in the final analysis, with a median age of 65 years (interquartile range [IQR] 54–77). The mean bias between the two pupillometers was 0.44 mm (95% Limit of Agreement [LoA] − 0.43 mm to 1.31 mm) for pupil diameter, 0.57% (95% LoA − 7.63% to 8.77%) for pupillary reactivity, and − 0.82 (95% LoA − 2.70 to 1.05) for NPi vs. QPI comparison. A very strong correlation was found between the two devices in terms of pupil diameter measurement (ρ = 0.91; 95% Confidence Interval [CI] 0.86 to 0.95; p < 0.0001) and pupil reactivity (ρ = 0.92; 95% CI 0.87 to 0.95; p < 0.0001). NPi and QPI were well correlated (ρ = 0.75; 95% CI, 0.62–0.84; p < 0.0001). In this cohort study, a significant statistical correlation between the measurements provided by two available pupilometers was found; however, NPi and QPI might not be clinically interchangeable.

Bibliografischer Nachweis

Publikationsdaten

Autor:innen
Carlotta Bandoni, Khalil Mounir, Francesca Iannuzzi, Andrea Berardino, Fabio Tarantino, Mohammed Rabi Andaloussi, Fabio Silvio Taccone, Denise Battaglini, Nicolo ’ Antonino Patroniti, Chiara Robba
Quelle
Journal of Clinical Monitoring and Computing
Publikation
2026-01-01
Band / Ausgabe
Nicht angegeben
Seiten
Nicht angegeben
ISSN / ISBN
1573-2614
Zitationen
0 laut Crossref
Referenzen
0 hinterlegt

Zitieren

Zitierfähiger Nachweis

Carlotta Bandoni, Khalil Mounir, Francesca Iannuzzi, Andrea Berardino, Fabio Tarantino, Mohammed Rabi Andaloussi, Fabio Silvio Taccone, Denise Battaglini, Nicolo ’ Antonino Patroniti, Chiara Robba (2026). A comparison between two indices derived from automated pupillometry devices. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-026-01490-4
RIS BibTeX CSL-JSON

Kontext

Themen, Förderung und Nutzung

Lizenzhinweise: Lizenz 1