Frag' FlorenceEvidenz. Klar. Anwendbar.
Uhr 7/8Sources Journal Tree
Easy Demo

Lokaler Crossref-Datenbestand · journal-article

Dual-flow convolutional neural network for automatic measurement of left ventricular ejection fraction and global longitudinal strain in echocardiography

Zisang Zhang, Ye Zhu, Shujun Chen, Yiheng Dong, Yiwei Zhang, Chun Wu, Ziming Zhang, Shuangshuang Zhu, Manwei Liu, Zhenxing Sun, Peige Zhang, Lili Jiang, Hongliang Yuan, Yongxing Zhang, Yuan Peng, Chunyan Xu, Chunyan Ma, Chunquan Zhang, Xu Huang, Xiaoshan Zhang, Yilu Shi, Xiaocong Wang, Qiaohui Su, Jing Wang, Mingxing Xie, Xin Yang, Li Zhang, Yuman Li

PLOS Digital Health · 2026

Vollständiger Abstract

Worum geht es in dieser Arbeit?

Left ventricular ejection fraction (LVEF) and global longitudinal strain (GLS) are essential for the diagnosis, clinical decision-making, and prognosis of cardiovascular disease. However, accurate assessments of LVEF and GLS by echocardiography are hampered by inter-observer variability, time-consuming, and labor-intensive. This study aimed to develop an automated method to accurately and rapidly assess LVEF and GLS. Based on the datasets of 500 patients (1,500 videos) from the internal center and 363 patients (1,089 videos) from four external centers, we successfully developed a dual-flow convolutional neural network called Echo-DFCNN, which allowed for synchronous acquisition of LVEF and GLS. We evaluated the performance of the Echo-DFCNN in a cardiac magnetic resonance (CMR) validation dataset composed of 67 patients. On the internal test dataset, the AI and manual measurements of LVEF demonstrated a median absolute error of 3.02% and a mean absolute error of 3.94%. AI-predicted LVEF showed good agreement with manually measured LVEF, with an ICC of 0.927, a bias of 0.89%, and a LOA of -10.91 to 12.69. For GLS, the median absolute error and mean absolute error between AI and manual measurements were 1.43% and 1.83%. AI-predicted GLS exhibited high agreement with manually measured GLS (ICC = 0.913; bias = -1.22%, LOA = -5.12 to 2.68). In addition, Echo-DFCNN maintained good performance when applied to external validation datasets. In the CMR validation dataset, the AI model showed good agreement with CMR measurements for both LVEF and GLS. Echo-DFCNN achieves simultaneous and precise assessment of LVEF and GLS in the study cohorts, demonstrating its potential for robust performance across a wide range of cardiac functions, different image qualities, and machine types.

Bibliografischer Nachweis

Publikationsdaten

Autor:innen
Zisang Zhang, Ye Zhu, Shujun Chen, Yiheng Dong, Yiwei Zhang, Chun Wu, Ziming Zhang, Shuangshuang Zhu, Manwei Liu, Zhenxing Sun, Peige Zhang, Lili Jiang, Hongliang Yuan, Yongxing Zhang, Yuan Peng, Chunyan Xu, Chunyan Ma, Chunquan Zhang, Xu Huang, Xiaoshan Zhang, Yilu Shi, Xiaocong Wang, Qiaohui Su, Jing Wang, Mingxing Xie, Xin Yang, Li Zhang, Yuman Li
Quelle
PLOS Digital Health
Publikation
2026-01-01
Band / Ausgabe
Nicht angegeben
Seiten
Nicht angegeben
ISSN / ISBN
2767-3170
Zitationen
0 laut Crossref
Referenzen
0 hinterlegt

Zitieren

Zitierfähiger Nachweis

Zisang Zhang, Ye Zhu, Shujun Chen, Yiheng Dong, Yiwei Zhang, Chun Wu, Ziming Zhang, Shuangshuang Zhu, Manwei Liu, Zhenxing Sun, Peige Zhang, Lili Jiang, Hongliang Yuan, Yongxing Zhang, Yuan Peng, Chunyan Xu, Chunyan Ma, Chunquan Zhang, Xu Huang, Xiaoshan Zhang, Yilu Shi, Xiaocong Wang, Qiaohui Su, Jing Wang, Mingxing Xie, Xin Yang, Li Zhang, Yuman Li (2026). Dual-flow convolutional neural network for automatic measurement of left ventricular ejection fraction and global longitudinal strain in echocardiography. PLOS Digital Health. https://doi.org/10.1371/journal.pdig.0001128
RIS BibTeX CSL-JSON

Kontext

Themen, Förderung und Nutzung

Lizenzhinweise: Lizenz 1