Frag' FlorenceEvidenz. Klar. Anwendbar.
Uhr 7/8Sources Journal Tree
Easy Demo

Lokaler Crossref-Datenbestand · journal-article

Evaluation of the accuracy of peri-operative CEUS in measuring the effect of microwave ablation treatment of uterine fibroids, in comparison with MRI

Marie Beermann, Gudny Jonsdottir, Annika Cronsioe, Klara Hasselrot, Helena Kopp-Kallner

PLOS One · 2026

Vollständiger Abstract

Worum geht es in dieser Arbeit?

Objective The objective of this study was to determine if peri-operative contrast enhanced ultrasound (CEUS) is as accurate as magnetic resonance imaging (MRI) in measuring the immediate effect of microwave ablation (MWA) treatment of uterine fibroids. Secondary outcomes were ablation ratio and proportion of recurrence of treated fibroids at 6 months. Methods The study was a prospective observational trial. Seventeen patients with symptomatic uterine fibroids were included and treated with percutaneous ultrasound guided microwave ablation. Before the ablation, the volume of the up to three largest fibroids were recorded with MRI and CEUS. At the end of operation, the ablated volume was recorded with CEUS and compared to MRI within a week. At 6 months, the ablated volume was again recorded with MRI and any sign of regrowth of the treated fibroid(s) was noted. Results A total of 19 fibroids were analyzed. The intraclass correlation coefficient (ICC) between ablation volume obtained by CEUS and MRI respectively was calculated to be 0.965 (95% confidence interval 0.909, 0.987). The Bland-Altman graph showed that the mean difference between volumes was –1.68 ml and standard deviation 22.60 ml, giving the limits of agreement (−45.98, 42.61). Regrowth of vascularized tissue was seen in 8 fibroids (47%). Conclusion CEUS can be used to evaluate ablation volume and ablation ratio and is useful for intraoperative estimation and guidance. It shows strong correlation with MRI. Regrowth of fibroids may occur even when initial treatment was technically successful.

Bibliografischer Nachweis

Publikationsdaten

Autor:innen
Marie Beermann, Gudny Jonsdottir, Annika Cronsioe, Klara Hasselrot, Helena Kopp-Kallner
Quelle
PLOS One
Publikation
2026-01-01
Band / Ausgabe
Nicht angegeben
Seiten
Nicht angegeben
ISSN / ISBN
1932-6203
Zitationen
0 laut Crossref
Referenzen
0 hinterlegt

Zitieren

Zitierfähiger Nachweis

Marie Beermann, Gudny Jonsdottir, Annika Cronsioe, Klara Hasselrot, Helena Kopp-Kallner (2026). Evaluation of the accuracy of peri-operative CEUS in measuring the effect of microwave ablation treatment of uterine fibroids, in comparison with MRI. PLOS One. https://doi.org/10.1371/journal.pone.0356141
RIS BibTeX CSL-JSON

Kontext

Themen, Förderung und Nutzung

Lizenzhinweise: Lizenz 1